Read the preserved original
13 scanned pages · 6.9 MB · PDF
Bibliographic record
- Author
- Weston A. Price
- Catalogue date
- 1897
- Type
- Article / paper
- Subject
- Dental technology and radiography
- Publication year
- 1897
- Publication record
- Ohio Dental Journal, XVII, 1897, 49-63; Dental Cosmos, XXXIX, 1897, 90-102; Dental Register, LI, 1897, 76-92
- Presented
- Ohio State Dental Society, December, 1896
- Presentation year
- 1896
- Historical bibliography
- Entry 3
- Record ID
- wap-bib-3
Catalogue notes
Listed in Price’s undated bibliography compiled after August 1933; individual custodian metadata has been checked; scan-level text verification remains pending.
Sources & provenance
Preservation details · custodian-16878.pdf
- Retrieved
- 2026-11-28T02:53:19+00:00
- Original URL
- Open source file
- SHA-256
eadd90be3718aadcb23f686621e0741b604fb65627d0fae9c38ed6752cab1983- Local file
- custodian-16878.pdf
- Publication / reuse
- Original publication before 1931, as identified in the cited publication evidence; original scan reviewed separately. US Copyright Office: https://www.copyright.gov/what-is-copyright/
Read searchable text
'tHE; RELATIVE EFFICIENC¥1 O~ VIlRIOUS' CURRENT CONTROLL~ '8,S
>I I " ! FOR.CATIlPHORESIS. .
' ,i l ' l
BX w.. A. : P. I-V ,CE, D .D.S., C L E VE LAN D, O.
. ; ; , 1( , ~ R~N~ b:efore the Ohio State D ental S ociety at Columbus , Ohio, Dec. 2 , 1896.)
h -: !tS"lby purpose in this paper to confine the discussion to the
various 'pri-nciples used, and no t to mention individual instruments;
.» ! ~ !I ; Irnust express my obligations to Professors Miller, Langl ey;
andCarter, all of Case School of Applied Sci enc e, fortheir ex cel
Ient assistance in 'experiments and 'tests, and for the use of very
excellent scientific apparatus, without which I could have done
hut ,little. . . . "', . .
- The function of. a controller is to furnish an electric current
abs olutely at the will of the operator. There are seven distinct
varieties of instruments on the market for this purpose. Let us
note the distinctive 'characteristics of each.
"First, the water rheostat, Fig. I, which is placed in series' with
the battery' and patient. One pole of the current is placed in the
hottom of a jar of water, and the other attached to a sliding
posr.: . The current passes through the patient, the water, and
PRICE .-CURRENT CONTROLLE1{S F OR CAT APH O R E SiS. 91
t he batteries in series, and is co nt rolled by varying the distance
between the end of th e sliding post and the bottom of the ja r, th e
amount of curr ent being controlle d by the am ount of water.
T he next, F ig . 2, is constructed on the sa me principle, except
that the current goes through fine German-silver wire instead of
FIG . 1.
Ll Q"GlD R E S IS T A X C El.
FIG . 2.
-
_ __T
F I G. 3.
-
C AR BON R OD R E S IS TAJ' CE.
water and the am ount of current is controlled and varied bv t he
am ount of wire put in the circuit. As in Fig. I, the current passes
th rough the patient, t he rhe ostat, and the batt eries in series.
Fig. 3 is identica l in principle, bu t instead of passing the current
t hro ugh fine wir e, it is passed throu gh g reen ca rb on of relativ ely a
. . .. _
' - ,,
THE DENTAL COSMOS.
very high resistance. The piece of carbon has little screws in
serted, very closely together, and the resistance is increased by
moving the contact lever farther from the end, to which is attached
the other pole of the current.
Fig. 4 is very similar to Fig. 3, except that it is another form
of carbon, namely: graphite baked on a piece of slate or glass.
The current is controlled by the position of the lever, which has a
metallic brush contact with the graphite. As in all the preceding
forms, the current goes through the patient, rheostat, and the
batteries in series.
FIG. 4.
-
GRAPHITE RESISTAN CF..
FIG. 5.
l------lp
In the next, Fig. S, the current is taken from the r ro-volt cir
cuit and passed through sufficient resistance, usually graphite or
powdered carbon, to cut it down to a sufficiently low potential.
Necessarily a much larger resistance is used. .
In Fig. 6 we have an entirely different principle for controlling
the current, which is taken from the lIO-volt circuit, and two paths
are made for it to flow through,-the one through the patient and
the other through a variable quantity of German-silver resistance
wire. The ratio of these currents to each other is inversely in
proportion to the resistance of their path. For example, if the
path L P M, Fig. 6, has a total resistance of 20,000 ohms and the
path L R M has a resistance of 2000 ohms, the relation of the cur
rent flowing through L P M to the total current flowing is as
PRICE,-CURRENT CONTROLLERS F OR CATAP H OR E SI S. 93
2000 is to 20,000 'p lus 2000, or one-eleventh, ten-elevenths flowing
through L R M.
By varying the relation of the resistance in these two paths the
current in both is varied; so since the resistance of the patient is
fixed, the current in that path, viz: L P M, is varied by changing
the resistance in the path L R M. ~ By increasing the resistance of
L R M the total amount of current flowing through the two paths
FIG. 6.
L
/10 «ocrs,
M
Fro. 7.
L
r
//0 VOLTS.
M
FIG. 8.
L
--L
-
-l T
M
is diminished in proportion to the total increase of resistance of
the combined paths. The next, Fig. 7, is similar to the last,
.ex cept that it has a three-way shunt. Two of them ar e constant,
viz: L P IvI, in which the patient is the resistance, and L S M,
which is a definite amount of German-silver wir e. The third,
L R M , has a variabl e amount of resistance wire, and the relative
amount of current flowing through these paths is varied according
to the relation of their resistanc es, always in inverse proportion,
and is varied by changing th e amount of resistance in L R M . In
94 THE DENTAL COSMOS.
the last, Fig. 8, the principle is identical with Fig. 6, the differ
ence being only in the source of current. In this case it is bat
teries instead of the r r o-volt circuit.
Just here let us review some of the laws of electricity. First,
the amount of current flowing depends on two things,-the
electro-motive force, or potential, or voltage, and on the amount
of resistance in the path.
The unit of electric pressure is a volt. The unit of current
strength is the ampere, and is the strength of current necessary ,to
decompose .09326 milligrams of water in one second. A milli
ampere is the one-thousandth part of an ampere. The unit of
resistance is an ohm, and is the amount of resistance through
which one volt pressure will produce one ampere of current. This
is simply one way of expressing Ohm's law, which is, that the
electric pressure divided by the resistance is 'e qual to the cur
rent. The electric pressure is expressed as the voltage, the resist
ance as ohms, and the amount of current flowing as amperes.
FIG. 9.
The volts over the ohms equal the amperes, or the volts over the
amperes equal the ohms. Doubtless you are all very ,familiar
with these terms, but I review them for fear some one is not, and I
shall use them hereafter entirely to express these quantities.
Let us next consider the conditions in the patient as the current
passes in through the medicine and tooth and out through the
body at some more or less distant point. The amount of work
done in a given case depends upon the amount of current flowing,
and the amount of current is fixed by the pain limit. Two things
are practically definite in every individual cavity, viz: the resist
ance through the patient and the pain limit. The former is rela
tively a different quantity in different patients and in different
cavities of the same patient, and as a "more or less remote point orr
the body is used from which to take the current. The average
resistance through the patient for about twenty-five cases was
about 25,000 ohms, varying all the way from 10,000 to 78,000
ohms, and in some cases even higher. The difference of resist':'
ance from the hand to the tooth and the cheek to the tooth is from
3000 to 5000 obms. It is almost incredible the amount that the
PlUCE.-CC KR E J\T CON T RO L LERS F O R CATAPHO RESlS. 95
re si stan ce ca n be varied bv the co nditio n of the cav ity. For ex am
ple, in a gi ven ca se th e i·esistan cc through th e patient {ro m the
cavity, wh ich was barely moist, to han d wa s 47 ,700 ohms. A
forty per cent. so lu tio n of co ca in in water placed in th e ca vity re
duced th e total r esist ance to 28 ,500 o hms, and placing the pad on
the ch eek in stead o f th e h and r edu ced it t o 23 ,800 ohms. Th ese
measurem ent s are approximately accurate, for th ey we re mad e by
stan dard instruments, most of th em fr om th e so urce named ab ove.
This is only a fair sa mp le of many cases 1 ha v e th e figures for her e
a t thi s time.
M easurem ents o f liquid resistan ces, s uc h as th e bod y, can no t be
mad e with a Wheatston e bridge as ca n solid subs ta nces, ow ing to
a se con dary indu ced cur re n t se t up by the elec trolysis of the flu id.
They can be st be ca lculated by Ohm's law. For ex am ple, an ac
curat e volt-meter reading in ten th s indi cates a difference o f poten
tial across th e pati ent of 5.7 volts, and a milliampere me ter r eading
in hundredths of thousandths of amp er es indicated t wenty o ne
hundred -th ousandth s : then th e resistan ce o f a patient wo ul d equa l
5·7 ov er t wenty on e-h uud re d-t ho nsa nd ths , or 28, 500 ohms. O r
dinary co m me rcial milliamper e meters that I h av e tri ed to u se and
compared with th e standar d instru ment s would not register with
an y degree of acc u racy through th e first few degrees of the scale,
-the o nly part needed,-Ilor w ould vol t-m et er s. Th e m illiam
pere meter used {or most o f th ese measuremen t s co uld b e adjus te d
t o read in any fraction of an ampere from on e-th ousandth to o ne
milli onth. Th e av erage resistance irom . the hand to th e -tongue
with small electrod es is about 9 0 00 o hm s, varyin g from 7 0 0 0 to
12,000 , a nd fr0111 the ch eek to the tongue a bo ut 5 ° 00 ohms, v ar y~
ing from 300 0 to 7 0 0 0 .' I t will be seen at a g la nce that b y far the
greate r part of th e resi stanc e of th e patient is in th e tooth, vary ing
all the way from TOOO o hms t o 70,000, a n av erage of probably n ear
2 0 00 ohms.
Measurin g cav ities at different st ag es durin g the ex cavating;
wit h as n early as pos sible th e same conditions, sho ws a g ra d ual de
c re ase of th e tot al resistan ce, in m an y cases man y th ousand oh ms.
Time will not permit of man y figur es o n th e relative resist a nce
of dentin taken fro m diff er ent parts of th e same tooth and fr om
different teeth , and th e variation of resi stan ce o f th e same section
of dentin ac cording as it is satu rated with different so lutions. For
ex a mp le, a lon gitudinal sect ion of fr esh de n tin almost dr y on th e
surface and five millimet er s in thickness had a resistanc e of 30,000
o hms; after deh ydrating and saturat ing w ith a fort y per cent.
solutio n of coc ain the r esi stance wa s reduced to 45 00 o h ms , and
o n ag ain deh ydratin g an d satu rating with a so clium- chlo rid sol u
ti on (comm on sa lt) the resistan ce was redu ce d to 307 0 oh ms.
Th e bearing of this o n th e process of cataphoresi s w ill dev elop
late!".
I s th e pain-limit vari abl e for a g ive n cav ity? Yes, though it is
normally almos t con stant, ex cept wh en medic at ed, in a case wh ere
there is no inflammation of th e dentin o r pulp , an d where th e
patient's gene ral nerve-tone is co ns tan t.
96 THE DENTAL COSMOS.
Is there any physical difference in a constant electric current of a
given strength, however it may be produced? This is probably
the most universal question in the minds of the members of our
profession at this stage of the advancement of cataphoresis. No,
there is not, according to the opinions of all electrical authorities
I have been able to find, provided the current be constant and per
fectly regular, and of a given strength. This will seem a contra
diction to the experience of many of you who have used currents
derived from different sources, as it did to myself.
The next may seem a greater contradiction to some of your
experiences. Is there any difference in the physiological effect .of
a constant and perfectly regular electric current, however it may
be produced? Provided the conditions remain the same and it is
without variation, answer, no. I mean by that, that a current of
one .ten-thousandth of an ampere produced by passing a current
of four volts through 40,000 ohms resistance, say 25,000 ohms
resistance in the patient and 15,000 ohms resistance placed in the
circuit, will cause identically the same amount of pain as a current
produced by passing a current of eighteen volts through 180,000
ohms resistance, or a current produced by passing seventy-two
volts through '7 2 0 ,000 ohms resistance, or a current produced by
passing one hundred and eight volts through 1,080,000 ohms re
sistance; provided it is turned on in such a way as not to produce
shock. I have done this frequently in my practice as follows:
The reflecting galvanometer was set to read two hundred and forty
points to the milliampere. A current with a difference of poten
tial between the poles of the batteries of six volts was allowed to
pass through the patient and some resistance. The resistance was
cut out gradually until the patient felt a definite sensation of pain.
At this point the milliampere meter indicated one hundred and
forty-two points, or 142-240 of a milliampere. This current was
cut off carefully. Next a current with a difference of potential
between the poles of the battery of eighteen volts was allowed to
pass through a much higher resistance , and the patient instructed
to give a signal when the same definite sensation was felt by re
ducing the resistance, which he did when the needle stood at just
one hundred and forty-two points. This current was cut off and
one of ·twenty-one volts through a higher resistance passed, and
the patient instructed to signal when the same definite sensation
was produced by cutting 011t the resistance. He did so, and the
needle stood at just precisely one hundred and forty-two. This
was stopped and forty-eight volts difference of potential passed
through a higher resistance, and the patient's signal was given
when the· needle was at just one hundred and-forty-two. Then a
current of one hundred and eight volts was adjusted in the 'same
manner, and the signal came when the needle was at just one
hundred and forty-two points, great regularity being required in
cutting out resistance.
I have done this frequently with myself and with a great
many of my patients, and have always gotten the same results,
though some patients could not determine a definite sensation as
PRI CE .- CURRENT CON T RO L L E RS FOR CAT A P HO R E S IS. 97
accurately as oth ers. I have sufficient apparatus her e, and will
assist any of you to mak e the experiment upon yourself at the close
of the session. If you try th e experiment, be sure to fast en ·the
elect ro des firmly in their re spective position s, and do not disturb
them a part icle throughout all the tests. I think I can demonstrate
it so you all can see with th e reflex 'pro duced in thi s fr og's 199.
Y ou see that by turning th e current o n very gradually, so as not
to produce a sudden stim ulation, th ere is a ctually no difference in
the an gl e of contraction produ ced by these different cu rre nts .
This means, if all the condition s necessary hav e be en cov ered, that
any apparatus that will perfectly cont rol th e current is ju st as go od
as any other. . But have all the co nditions ne cessary been cov ered?
N o ! I hav e here lik e resi stances of the variou s substances used for
that purpose, eac h with a total re sistan ce of 45,800 ohms , and if
the stateme nt is tru e that a current of definite strength 15. ph ysi
cally th e sam e it matters not how it is obtained, then the same
elect ro -mo t ive for ce passed through th ese ' different materials of
equal resi stance should give th e sam e ph ysiological effect. Y ou
put this 'elect rode on your tongue and yo u cannot distinguish an y
difference in th e sen sation. T he sen sation of feelin g seems t o be
identical with th e indication s presented in th e refle x of this fro g's
leg. These resistan ces are Ge rma n-silver wire, wat er, and graph
ite, and ar e connected alternately on thi s switch-b oard for con
venienc e, and you cannot det ect an y perceptible differ ence in th e
reflex of th e fro g or th e sens ation on your tongue by passing the
current through on e or another of these substances. T his answers
the question wh ether anyone substance used as the medium of
re sistan ce produ ces any more or any less pain than an y othe r sub
sta nce, all the condition s remaining the sam e. I t ce rtain ly does not,
although we hear so many assertion s to the contrary.
L et us repeat what was asserted before, that a const ant and per
fectly r egular current of definite stren gth will produce th e same
ph ysiologi cal effect under the same condition s, no matter how
produced. If you appl y t wo electrod es to your t ongue, it is a
broken circuit, not a cons ta nt one. Wh at difference does it make
wh eth er a current is co nsta nt or not ? I wish you could each try
this next experiment upon your own tongue, although this frog's
leg reflex will demon strate it. \Ve will use as nearly as possible
the same current st re ngt h in every .case as indicated by this gal
vanometer. In the first case we WIll use a voltage of one and a
half volts and pa ss it throu gh 3840 ohms resistance; in the n ext,
eig hteen volt s through 45.800 ohms ; and in the next , one hundred
and ten volt s through 282.05 0 ohms. In each we will g et a curre nt
stre ngth of thirty-nine one-hundredths of an ampere. With the
first, with a sudden make or br eak of circuit, you see but a sligh t,
though definite, reflex of th e fro g 's leg; with th e next, thou gh
identically th e sam e amount of cur re n t, there is a decidedly
g rea ter reflex; and with the last, a still g reater ' increase of
th e strengt h of the reflex . What is the explanation? Sup
pose you have three pumps so reg-ulat ed with governors that
they will keep ju st thirty-nin e barrels of water circulating per
THE DENTAL COSMOS.
minute through each of three separate complete circuit systems of
pipes. The first system has just enough miles of pipe so that the
pressure that accumulates at the pump to force that amount of
water around the circuit per minute is one and a half pounds to the
square inch. In the second system there are enough miles of pipe
so. that the pressure at the pump as it sends out the water is
eighteen pounds per square inch. In the third there are just
enough miles of pipe to .prod uce a pressure of one hundred and
ten pounds per square inch at the' outgoing side of the pump, in
order to force the thirty-nine barrels around through the circuit
per minute. Now suppose in the first a check of some kind is put
anywhere in the circuit so that no water can get past; then the
pressure will rise all the way along in the pipe as far as the check
to one and a half pounds per square inch, that being the limit of
the pump's pressure. Suppose a check is put in anywhere in
system No.2, and the pressure will rise all along that system to
the check to eighteen pounds per square inch. And so with the
third system; the pressure all the way from the pump to the check
would rise to one hundred and ten pounds per square inch. Let
us suppose one pound to be the pressure required to force thirty
nine barrels of water through one mile of pipe per minute; now
suppose these checks were to be suddenly removed, what would
be the strength of current for the first instant? In the first case
it would be at the rate of one and a half times thirty-nine barrels
per minute, or fifty-eight and a half barrels; in the second at the
rate of 702 barrels per minute, and ill the third at the rate of 4~90
barrels per minute. This rate would last for only an instant, and
would immediately decrease until it reached its normal rate. The
time this increased rate would last could hardly be calculated, but
it exists, and we have all observed it at the hydrant. This is pre
cisely what occurs in the circuit of an electric current when it is
broken. This produces what is called the throw of a needle of a
current meter, some of which are constructed to not register this
first impulse. Although there is such a difference in the reflex
produced by these two currents by a sudden make or break, you
will see there is no difference in the amount of work they will
accomplish, for we will now connect them with these tubes of iodid
of potassium, and the amount of electrolysis is identical. If I turn
these various currents on slowly enough, there is no perceptible
difference in the reflex produced on this frog's leg or the pain pro
duced on the tongue or in a tooth. It is not necessary to break a
current to get this effect, for it takes place to a greater or less
extent with every variation of potential or of the total resistance of
the circuit.
There are certain facts accompanying the process of cataphor
esis which materially determine the requirements of a satisfactory
controller. First, the current strength cannot remain constant; it
must .be continually increased as the pain limit will admit, owing
to the anesthetizing of the tooth. This is accomplished in two
ways,-either by increasing the voltage or by diminishing the re
sistance of the circuit. The former causes pain if done too rap
P RICE.- CUIZRE NT CON T ROLLE RS F O R CATAPHORESI S. 99
idly or in to o large quantities, and that in so me case s as low as
one-twentieth of a volt; th e latt er pro duces pain if diminished too
rapidly or in lao large qu antities. Even if there are 5 0,000 ohms
re sistanc e in th e circuit and the t otal is redu ced by 100 o hms, it
will frequently produce pain. A no the r fad attendin g' this opera
tion is that the total resi stance of th e circuit ca nnot De kept con
stant. Any movem ent of the elec tro des , espec ially th e o ne
in th e t ooth, thou gh ever so slight, ma y var y the tot al re sistance
of the circuit to almost any amount. No operator sho uld ever
attempt to hold the electrode in hi s hand, for it is imp ossible t o
prevent causing so m e variation in resistance o l th e circuit at that
poin 1. It is not neces sary. Flexible fine gold or platinum wire
(which by the wa y th e dental dep ots would do well to furni sh) ,
about four one-thousan dths of an inch in diameter, packed into the
cavity with cotton carrying the medicament will be infinitely more
sat isfactory, or any of the m an y ex cellen t clamp s for that purp ose.
In ov er three hundred cas es 1 have not required t o hold th e an ode
in a dozen. A special device 'can be made in a couple of minutes
for any specia l case. Another source of variation of th e total
r esist ance is fr om the cavity or the pad drying out, and when
moistened producing shock by a sudde n increase of current, due to
lowering the t otal resistance. It is ab solutely impossibl e for us t o
keep a constant and perf ectly regular current. ,We would not if
we could, and we could not if we would.
Since the current cannot be kept con stant, we sh ould, for th e
least risk of pr oducing pain by variations of current, keep the
total resi stance in the circui t as low as pos sihl e. It using batteries
with resi stance in series, do not use any m ore cells than will do the
work; for while if th e curr ent were to remain ab solutely constant
'there would b e no difference in the pain pr oduced, since that is
clearly impossible, and there must and will be variati ons, for the
many reasons given, there will be more intense shocks caused by
th e same variation. If you g et an apparatus in which th e resist
ance is in series wi th the patient and batteries, be sure it is wired
so yo u can turn on one or more cells at a time. I have had ca ses
where 5 ° ,000 o hms resi st ance in se r ies with one ce ll and the
patient p roduced unb earable pain, an d the resi stance had to be
in creased to 108,000 ohms. \:Vl1 at would have been the effect
if I could not use less th an twelve or fifte en or twenty cells in
series, or if m y total resi stance did not exc eed 1000 to 5 000 ohms,
as so me do? An apparatus to be sufficient for all th ese ex tre m ely
sensiti ve cases sh ould, if resistance is put in series, have a total
variation of not less than 100,000 oh ms. Probably not over ten
per cent. of ca ses will require over 70,0 0 0 ) nor over twenty-five
p er cent. require over 4 0 ,0 00.
Let us next consider th e othe r principl e for co ntro lling the cur
rent, viz: by means of a shunt. Suppose th e resistance of L P M
(Fig. 6) to be 25,000 oh ms , which is, of course, th e resistan ce of
the patient, and the difference of potential betwe en Land M is one
hundred an d ten volts, what must be the resistance of L R M to
cau se one milliam pere of current to flow throu gh L P M? I t will
100 THE DENTAL COSMOS.
require some introduced resistance at L or M to limit the amount
of current within easy control. Let us say two lamps of 275 ohms
resistance each. According to the law of inverse proportions,
the current flowing through L P M is to the current flowing
through L R M as the resistance of L R M is to the resistance of
L P M. The resistance of L R M approximately is 160 ohms.
Suppose the resistance of the patient to be 40,000 ohms; then
L R M will be approximately 325 ohms. If L R M equal 10,000
ohms, then to give one milliampere L R M equals approximately
58 ohms. You will see at once that the amount of resistance
placed in the shunt L R M is no indication of the amount of cur
rent flowing through L P M, unless you know the resistance' of
L P M. Hence, since the resistance of patients is such an uncer
tain and widely varying quantity in different cavities, it is impos
sible to arrange any scale of indication of the actual amount of
current any given case is getting. If the resistance of the patient
was universally one ohm or any other definite quantity, or any
approximate quantity, then an arbitrary scale could be just as .
approximately correct. Under the existing positively uncertain
conditions, they have practically no definite significance. . This
includes the indicators of so-called volt selecters. This problem
of shunts is very complicated, and I will dwell on it at greater
length in my closing discussion.
What is the effect of breaking or making the current of one path
of a two-way shunt ? You get the actual true current strength as
the first sensation. For example, suppose the resistance of a pa
tient to be 20,000 ohms, and one-tenth of a milliampere is flowing
through the patient's circuit, L P M, then the difference of poten
tial between the two sides of a patient would be two volts, and the
patient would get the same amount of shock that he would from a
cell giving two volts, when there was no resistance in series. 1£
the resistance of a patient were 50,000 ohms, and one-twentieth of
a milliampere of current was flowing, then the difference of poten
tial across the patient would be ten volts, and the patient would
get the same shock he would from five cells in series giving two
volts each. You see by this method the minimum possible shock
is given, and since . the variation is inevitable in the current
strength, this is a very important item. This is very easily demon
strated by the frog's leg reflex and felt by the tongue.
Now a word as to the capacity and necessary requirements of
any controller to do all cases absolutely painlessly and thoroughly,
which is possible in ninety-five per cent. of cases. The instru
ment should be able to furnish a difference of potential across the
patient of at least twenty volts, for actual measurements of cases
show that some will finally and properly stand that amount of cur
rent. With an instrument taking the current from batteries with
the resistance in series this simply means that there be enough
cells to produce that voltage: butif a shunt from a r ro-volt circuit, '
it should have a variable resistance in the shunt in proportion to
the permanent resistance P11t in the circuit. If a shunt from bat
teries, the batteries should have a total voltage of thirty volts, and
PRICE.-CURRENT CONTROLLERS FOR CATAPHORESIS. 101
the cells should be arranged with a cell selecter and a high vari- .
able resistance. This is one objection to a shunt on cells: that a
greater variable resistance is necessary, owing to the lower poten
tial, unless a very large number are used. It is not a practical
objection, however, since the alternative is very practicable. It is
clearly evident that a shunt is the most satisfactory means of con
trolling the current by far, from the experiments we have made,
no matter from whence the source of the current. The economy
of the cells is an important factor, and since a shunt of low resist
ance is simply a short circuit, the cells will not last so long as if
less are used and a higher resistance in the shunt.
What are the shortcomings and points of superiority of these
different methods we have considered?
First. The water rheostat. If platinum electrodes are used in
distilled water, and the total resistance is high enough, not less
than 100,000 ohms, which means a column of about twelve inches,
according to the size of the electrode, and the mechanical working
of the machine is such that a perfectly smooth and easy control is
had of the current, it is just as good as any using identically this
same principle. The majority of this variety have not one-quarter
enough variation of resistance. Four inches of lake or river water
has about 500 ohms resistance, and of salt water not 1000. Draw
vour own conclusions.
. The German-silver resistance in the circuit in series is efficient
accordingly as it is finely divided into steps or is sufficient in quan
tity. There should be 100,000 ohms, with steps of not less than
roo ohms for an ideal machine. It is probably as clean and dura
ble as any. It is a fact, however, that the metallic contact connec
tions, whether the points of a switch or a brush on a coil, are not
constant, and I have not seen an instrument in which they were
a part that would not show a fluctuation of current caused by
them; not enough to be an excluding objection, if kept clean.
The objections to the metallic contact points in the green carbon
stick are the above, also that there is not possible a great enough
total variation of resistance, and the contact points cannot be
closely enough together to prevent shock unless a very large
board is used.
A system in which, as ill Fig. 5, there is a very high resistance
in series in the r ro-volt circuit is not consistent, nor could its
results be satisfactory. A difficulty with any form of lever to be
moved by the hand over any carbon or graphite surface is that
the distance it can be moved without producing shock is too small,
unless the instrument be larger than those generally used. Pow
dered carbon is a very variable resistance. Where a three-way
shunt is provided, morc variation is required in the variable shunt,
if its resistance be low. It is considered a guard against shock
from variation of potential.
We have not referred to the automatic devices for increasing the
potential or diminishing the resistance. All are good and are
practical. Many are excellent, but need constant attention. This
point has been overlooked by most manufacturers.
VOL. xxxrx.s--B
102 THE DENTAL COSMOS.
What are the logical conclusions to draw from the foregoing
experiments?
(I) A method in which the principle of the device used for coo
trolling the current is' a shunt is preferable to any where the
resistance is put in series in the circuit. .
(2) Keep the total resistance of the circuit as low as possible.
(3) Remember that the sensation produced by suddenly break
ing the current is very similar to that of .making it suddenly, not
identical, however.
(4) If the IIO-volt current is practically without variation of
potential, it is .of almost equal efficiency with batteries as a source
of current, provided a shunt system is used; not so if in series. It
is not fairly constant, however, in all cities, nor in branches where
the mains themselves are fairly constant. In many cities the direc
tion of the current is frequently changed. Both of these are im
portant items.' The former would produce shock and the latter
absolute failure, and I believe frequently does.
(5) Always keep just below the pain limit.
(6) The fluctuations felt sometimes by the patient are not
always due to variations of current; they frequently are of physi
ological origin, which is easily proven. .
(7) After testing for over six months on a dozen different varie
ties of instruments, and r ecording over 300 cases in which absolute
failures were' about two per cent., partial failures about eight per
cent., and in which over thirty pulps were drilled out absolutely
'without pain, I have concluded that some principles used are . in
consistent and the instruments using them failures; some others
all right in some cases; some excellent, considering, but as yet
none are just what the profession should 'demand and will some
day get.