Preserved here

The Science of Dental Skiagraphy

Weston A. Price · 1900

Read the preserved original

22 scanned pages · 2.3 MB · PDF

Bibliographic record

Author
Weston A. Price
Catalogue date
1900
Type
Article / paper
Subject
Life, practice and research
Publication year
1900
Publication record
International Dental Congress (III) Transactions, II, 1900, 345-370; Dental Cosmos, XLIII, 1901, 483-503
Presented
International Dental Congress, Paris, France, August, 1900
Presentation year
1900
Historical bibliography
Entry 7
Record ID
wap-bib-7

Catalogue notes

Listed in Price’s undated bibliography compiled after August 1933; individual custodian metadata has been checked; scan-level text verification remains pending. Publication dates vary between the historical bibliography and the individual archive record; see source manifestations.

Date comparison: Bibliography publication year: 1900; Item publication year: 1901 Compare source

Sources & provenance

Preservation details · custodian-16885.pdf
Retrieved
2026-11-28T02:44:45+00:00
Original URL
Open source file
SHA-256
f9046d97bde5bb262afb28238fd23eb5a9791ed869197acab2dc9384c40e164c
Local file
custodian-16885.pdf
Publication / reuse
Original publication before 1931, as identified in custodian publication statement; original scan must be reviewed. US Copyright Office: https://www.copyright.gov/what-is-copyright/
Read searchable text

Uncorrected text extraction. Consult the scan for exact wording, tables, and illustrations.

                                                                                                                          jt+ .1




  The Science of Dental Radiography .


By WESTON A . PRICE, D .D .S" ., VLE ., CLEVELAND, orllo.




 (Lecture and demonstration before the Third International Dental Con g- ress, Paris
                                                                           .)          ,Augstr9oandepifmthDrACosfMay,iq
    The Science of Dental Radiography .

By WESTON A. PRICE, D .D .S ., M.E ., CLEVEL,AND, Oxlo .



   (Lecture and demonstration before the Third International Dental Congress, Paris,
          August, i9oo, and reprinted from the DENTAL Cosmos for May, i9ox . )




   THE purpose of this communication is to establish a higher and
more general appreciation of the splendid services the Roentgen
rays can render in the various branches of dentistry, and to give a
description and demonstration of the necessary apparatus and the
technique of its practical application, with a report of important
new developments . Owing, however, to the vastness of the sub-
ject and the shortness of the time available, our talk must be very
incomplete and disconnected .
    In the routine of making a practical application of the
Roentgen rays in dentistry we have to deal with the following items
or factors, each of which greatly affects the others,--viz :(a) The
source of the X rays ; (b)the exciter ; (c) the patient ; (d) the
photographic plate or screen ;(e) the developing and printing, and
 (j) the interpretation of the results . Of these the patient, or con-
dition to be examined, is the fixed factor to which the others must
be adapted . The science of dental radiography consists entirely in
thoroughly understanding these factors and their relations to each
other.
    First, the source of the rays . For all practical purposes this may
be limited to the Crookes tubes of the focus type . The Roentgen
rays are emitted at all hard surfaces struck by the cathode rays
produced in a high vacuum . These rays are propagated in practi-
cally straight lines from the negative pole (or electrode) of the
tube ; to concentrate them the cathode or negative pole is made con-
cave, and for this aluminum is generally used . In the earliest tubes
the cathode rays were allowed to strike the glass walls of the tube,
but later a piece of metal (usually platinum) was placed on the
anode, or positive pole, at the point of true focus of the concave
cathodic stream,-for which reason the positive, when so arranged,
is often spoken of as the anti-cathode, instead of the anode .
    The rays are emitted in all directions from the point upon which
the cathode rays fall . This can be most easily demonstrated by
                                   2

 this lantern slide [exhibiting], which shows first the relation
 between the cathode (a) and anti-cathode (b), which in this tube
 may or may not be in the anode, it having another pole (c) to which
 the positive wire may be connected ; either connection will produce
 the same effect . Only a small portion of the field of X rays is
 shown in A in order not to hide the electrodes . The second view
 (B) of the same tube shows the true field of emission of the X rays .
    I must take for granted that you know the principal properties of
these rays, such as their invisibility and their power of penetrating
opaque bodies, which last property, together with that of producing
chemical action and fluorescence, gives them their value . Their
property of penetration tends to be in proportion to the density and
thickness of the substance through which they are passing, though
no exact relation has been found between its physical and chemical
properties and the amount of absorption the substance will exercise .
Most investigators agree that the four chief factors influencing it
are "density, thickness, molecular weight, and chemical constitu-
tion ." It is a universal fact, however, that twice the thickness of
any substance does not have twice the opacity, but from ten to
fifteen per cent. less . It is entirely upon this property of different
absorbability (for the X rays) of the various parts of the field
through which they pass that all radiography depends . In ordinary
radiography the differences in the densities are relatively great, the
substances being flesh as compared with bone, or a foreign metallic
substance as compared with bone or flesh . Very unfortunately the
differences in the absorbability of the various parts from which we,
in dental radiography must get contrasts, are small . This fact
necessitates the most exact adjustment of the various conditions,
which we shall consider later .
   The penetrative power of the rays varies through a very wide
range, from those that are stopped by a sheet of writing paper, or
a few inches of air, to rays capable of penetrating many inches or
even a foot of iron .
   In any branch of radiography we can have success only by select-
ing rays that have just the power which renders them capable of
penetrating the less opaque parts of the field and not the more
opaque, according to the particular iriformation wanted . It has
been because of neglect to comply with this law that practically all
the failures have been made . With tubes made under precisely the
same conditions, or the same new tube under different conditions
of exhaustion, it may be said that the penetrative power of the rays
is in a constant proportion to the degree of exhaustion . This ;s not
a universal law, but, according to Dr . Rollins, obtains only so long
as there is an abundance of absorbed hydrogen in the cathode, the
ions of which are the carriers of the electrical charges in the tubes
exhausted from air containing water vapor .
   It is generally the case, however, that the longer a tube is used
the higher the vacuum gets, and also the greater the penetrative
power of the rays . Time will not permit of an exhaustive discus-
sion of the precise factors that are recognized as determining the
penetrative power of the rays, but through a wide range it is
in a ratio with the velocity of impact on the anti-cathode . Thus a
tube having . a resistance which is an equivalent of one-half inch
air-gap will ordinarily produce rays having very low penetration,
and by putting a. two-inch spark-Lyap in series with the tube, whether
from a coil or static machine, its penetrative power will be very
many times greater provided the character of the secondary dis-
charge is right .
   With a proper apparatus this use of a series spark-gap is an im-
portant factor in tne adjustment of the penetration of a tube in
practical work. I will throw a couple of pictures on the screen to
illustrate [exhibiting] . These show the penetrative power of a
certain tube with and without a series spark-gap, all :other condi-
tions being the same . They were made by placing some teeth upon
a wedge "made of aluminum which tapers from about three-quarters
of an inch (2 c .m .) to 0 .65 m .m ., the whole being placed upon a sen-
sitive filin . Without the spark-gap the penetration of the tube was
so low that it but slightly impressed the film through the thinnest
portion of the aluminum wedge, while with the series spark-gap it
penetrated it to some extent throughout its entire length, producing
shadows of the teeth throughout its, length .
   This means of varying the penetration has not a wide -enough
range to be universal, and is especially limited with the ordinary
sizes and forms of apparatus . We must depend chietiy upon the
selection of a tube for the case in hand, adjusting it-to the proper
condition . . This can be done by varying its temperature, the quan-
tity and quality of the exciting current, and the nature and quantity
of its contained gas . This latter is done chiefly by heating potash
crystals contained in an auxiliary bulb and evaporating from them
their water vapor, or by introducing gas, usually hydrogen, electro-
lytically: In the former the potash is usually heated by the electric
current to the tube, being shunted off to a circuit containing the
potash bulb, with a variable spark-gap in series . When, by the
heating o£`` .the potash and consequent liberation of water vapor, the
vacuum of the tube is reduced so that its resistance becomes less
than that of the path through the potash, the current passes through
the tube.
   All of the many tubes employing this last principle that I have
used haye had. two serious defects for our work : First, they are
not made with a long enough spark-gap (thus not allowing ofhigh
enough penetration), and they change their vacuum very easily in
operation . . They doubtless are excellent for ordinary radiography,
but the capacity or penetrative power of tubes for our work, par-
ticularly when working on adults, must be very much greater than
for ordinary radiography ; because the bone that in general surgery
is required t~.o cast a shadow (or, in other words, stop the X rays) ;
in our work must be penetrated, and must not cast much shadow,
or at least not nearly so much as the tooth, or root, or root-filling,
etc„ that are within it . We will return to this part of the subject
later, and will now briefly consider another source of rays for
radiography,-viz ; those rays emitted from the newly-discovered
elements, pollonium, radium, and actinium, which have been diS-
                                 4

covered within recent months by M . and Mme . Currie . I had much
difficulty in obtaining specimens for experimental work .
   The rays are emitted continuously from the powdered salt of
the metals, usually the sulfite, and have the properties of penetrat-
ing opaque bodies, of producing chemical action (as affecting a
photographic plate), and fluorescence of certain salts . They act
very similarly to the Roentgen rays . They have not so great pene-
trative power as the latter, as far as yet determined .
   I have found them to behave very similarly to such X rays as
are produced from an exceedingly low vacuum tube, and have made
dental radiographs with them, but, as you will see by this slide
 [exhibiting], they do not penetrate the bone sufficiently to make
contrast between it and the tooth . You will also note a very great
lack of definition, which is due to the size of the emitting surface
and its nearness to the photographic plate. We hope these defects
can be corrected by securing greater penetrative power, which will
allow of greater distance, and by a substance producing greater
volume or quantity of rays, which will admit of a smaller quantity
being used or a smaller emitting area .
   This picture was made through a sheet of aluminum in which
was placed I gram (15 grains) of the salt, and which was held
close to the teeth,-two central incisors standing alone in the
inferior arch . This method is so simple that we may well anxiously
hope that it may develop favorably . Don't wait for it, however .
I have found the rays emitted from these salts to have marked
physiological effects, especially in certain skin affections, which I
shall report subsequently . As yet this means of producing dental
radiographs is purely experimental, and I only recommend it as
such .
   Returning to the Crookes tube method, we will next consider the
 various methods of excitation, which may be either a Ruhmkorff
coil, usually called an induction coil, or a Tesla coil, or a static
machine .
   Time will allow of only the most general statement, both as to
the methods of using them and as to their relative merits . The
first, the induction coil, as its name implies, consists of a primary
coil of coarse wire of a few turns wound around a soft iron core,
around which is a coil of very many turns of very fine wire ; and the
whole is simply an ordinary transformer with a very high step,
with a condenser attached to the primary . It requires about twenty
thousand volts (Trowbridge) per inch to jump across any distance
in air, between pointed terminals,-up to about fifty inches, or one
million volts .
   On account of laws of inductance and conditions of stress obtain-
ing upon the make and break of currents passing through coiled
wires, or coils passing around soft iron, it becomes necessary to
have the current in the primary of the induction coil intermittent
in order to produce the high tension or voltage necessary in the
secondary current . In practical radiography the method, and
nature of this make and break of the primar)-is pf, quite as great
significance as the make of the coil . A good vil~rating hammer-
'break is perhaps the most simple, but it is not the most efficient ;
 the later forms are, however, greatly improved . An ideal break
 must give a sudden and perfect make and break without a spark,
 with more time for the period of make than for break .
    There are many forms on the market to-day of the following
 types :
    A revolving armature with a blast of air to break the spark, of
 which the Edison is the chief example, and which, considering its
 mi"nor .efficiency and great noise, is far from acceptable . Dr . Wm .
J . Morton and Mr . Caldwell ; .both of New York city, have devised
 much more efficient interrupters of this rotary type, but, so far as
 I know, they are not on the market yet .
    Another type is that of a metal point dipping into a mercury bath
 under a non-conducting liquid like kerosene or a deep layer of
alcohol . These have been chiefly made in Europe, and are some-
times excellent, being capable of great variation ; but as usually
 constructed are very noisy, owing chiefly to the cheap, poor motors
 used. In most of the makes on the market too small an eccentric
 has been used, giving the plunger too short a stroke . If the plunger
 is made very thin, like a ribbon spring, instead of round and stiff,
 it produces very much less splashing . A Ritter dental lathe motor,
which so many dentists have, is superior to anything on the market
for this purpose, for on it the apparatus can be constructed to run
almost noiselessly and subject to the most delicate adjustment of
speed .
    Another type of interrupter, and a very excellent one, consists of
a jet of inercury thrown against : revolving metal contacts . It was
designed by Mr . Isenthal, of London .
    In mv judgment, not any of the above types of interrupters, or
any others I have known of, are capable of so wide and satisfactory
variation as certain particular forms of Wehnelt and Caldwell elec-
trolytic interrupters . The former usually consists of a large elec-
trode of lead, or preferably silver, and one of a small surface of
platinum, both placed in a dilute solution of sulfuric acid . The
latter consists of two lead plates or electrodes in solutions of sul-
furic acid ;' and separated by a non-conducting partition, ustially
glass, through which there is a small hole or window . They
greatly increase the capacity of the coil, and with them no con-
denser is used .
    After much experience, I must stronglv advise against the use-of
a platinum point fused into a glass tube, for it is only a certain very
definite amount and shape of surface of platinum that will give the
maximum results with each particular tube and coil ; besides, the
quality of rays can be varied considerably from the same tube by
having a perfectly adjustable platinum electrode .
    The Wehnelt interrupter works best on an alternating current,
and produces almost a undirectional current in the secondary when
properly adjusted . The form I presented before the Ohio State
Dental Society last December .(see February, igoo, DENTAL
Cosiuos, and the Ohio Dental Journal, rgoo) still proves to be the
best I can find . It consists of three independent platinum points,
                                     6

and is made by soldering pieces of platinum wire of three or four
inches in length and size about Nos . 16, 20, and 24, respectively
 (B: W. gauge), to copper or silver rods the same size, and placed
inside clay pipe-stems or, better, glass barometer tubes, in which
they are easily adjustable and which are not disintegrated by the
heat or acid . The pipe-stem or glass tube is placed in a perforated
rubber cork, through which it is easily adjustable into the bath cqn-
taining the lead electrode . Owing to difficulty of finding clay pipe-
stems of small enough bore, I have recently been using in the . same
way, and with perfect success, pieces of glass barometer tubing,
well annealed, which work excellently ; it can be gotten with small
bore, of varying sizes, and very thick walls . I here show this good




                         Electrolytic Interrupter.


working form of Wehnelt interrupter as I have arranged it . Use
a glass battery jar of about two gallons capacity, and make the top
of hard rubber or paraffined wood . A single focus tube is used,
and the definition seems quite as sharp as when the continuous cur-
rent is used . I regret that the distance to travel prevented my
bringing a complet,~ set of various forms of interrupters, and also
the other apparatus which I have found best suited for our work .
   The Caldwell interrupter is usually made by perforating a large
test-tube, placing a lead electrode within it, and placing the whole
in a larger vessel containing dilute sulfuric acid and another lead
electrode. The interruption takes place in the small hole . It
works best on the continuous current, and in the best forms the
size of the hole is regulated by means of an adjustable tapered glass
point . It must be. remembered that every interrupter must be
adjusted to the particular coil with which it is to work, and both
of them to the tube and the quality of rays desired . A variable
                                    7
 resistance or rheostat should be used in the circuit of the primary
 with all interrupters .
    The static machine may be any of the many forms of rotating
 glass or hard rubber or mica plates, but must be of very large
 capacity, and hence large size . Different forms have advantages
 and disadvantages, such as being greatly influenced by moisture
 or not at all so, changing of polarity, relatively enormous size, and
 inability to light tubes of high penetration unless of very great size .
 I shall judge, from the standpoint of a dentist and his peculiar needs
 in radiography, and what I have to say regarding static machines
 for lighting X ray tubes does not apply to the general physician's
 use of it, which is entirely different . It has but one strong point in
 dental radiographic work, and that is the steadiness of the glow of
 the tube for fluoroscopic work, which is not, as I will show later, a
 strong argument for its use in dentistry, since of necessity we shall
 use that method rarely ; besides, it does not produce a noticeably
more steady glow than can be secured with a Wehnelt interrupter .
And, again, it only produces that steady glow when the resistance of
the tube is very low, and consequently its penetration feeble, or
 otherwise when the capacity of the machine is enormous, which
requires great size . True, tubes of so-called high penetration can
be lighted by many of them by means of the series gap or Leyden
jars, but this immediately produces the slight flickering we were
giving it the credit of obviating . Moreover, the penetration re-
quired for our work, to paroduce the best results, is so very great
that not one static machine in many hundred will light the tubes .
I speak advisedly, for I have visited very many operators and
manufacturers, both in America and Europe, to investigate these
matters . Some very few operators in general radiography are get-
ting really excellent results, but they have very large machines .
    The various forms of Tesla coils or oscillators have much merit
for exciting X-ray tubes, but time does not permit of their explana-
tion further than to say that the nature of the current they produce
is always alternating, and is of very high tension and frequency .
Their current illuminates a tube beautifully and abundantly, and
consequently they are capable of producing pictures with short ex-
posures . I do not consider it such an instrument as I should
advise for dental use, for the following reasons : On account of its
very high tension, much more danger occurs of puncturing the tube .
Most forms are not so easy and simple to regulate as a coil, and it
is a very noisy generator . The first two objections are overcome
by the skilled physicist, and hence it becomes an instrument better
suited for the physical laboratory than for the lay operator.
   In the patient, or rather the condition, to be radiographed we
have the most exacting conditions, to which all else must be adjusted
and adapted, and I say frankly that no physician, or physicist, or
layman can possibly do dental radiography very successfully unless
he be also a skilled dentist . By skilled dentist I mean most thor-
oughly acquainted with all the minute anatomy . of all the adjacent
parts, and particularly their relative densities and thickness . He
must also know thoroughly all the general operations and the den-
                                   8

 sity of the materials commonly used, and also must know thor-
 oughly all the pathological conditions that may be present .to be
 looked for or recognized, especially within the teeth and bone . It
 is only by correctly judging the relative densities of the various
 parts in question and adjusting the penetration of the rays so that
,they will penetrate the less dense and not the more dense parts that
 we get any information, for our information is only obtained from
 the shadows produced . Without this information the operator is
 as certain of failure as a hunter going out to hunt game with his
 eyes blindfolded and not knowing anything about his ammunition,
 which is of the greatest possible variety .
    Fortunately, dentin has a slightly greater opacity to the X rays
 than bone, and enamel more than dentin, and gutta-percha root-
 fillings, cement and metal fillings, or broken steel instruments still
 more than enamel . At the same time the density or opacity of the
 bone increases rapidly with age,-much more rapidly than that of
 the dentin ; consequently in making radiographs for adults or old
 people very much more care must be taken to use rays of just the
proper degree of penetration . In like manner, since the opacity is
 in nearly direct proportion to the thickness, such variations as are
 caused by the presence of a pocket in the bone, from whatever
 cause, will be shown in the most minute detail if rays of just the
 proper penetration have been used . So also natural cavities, such
 as the antrum and inferior dental canal, must be familiar to the
 operator in every detail,-as normal position and possible complica-
 tion . A splendid radiograph of bone will show large bloodvessel
 and nerve canals, and will also show minutely the cellular structure
 of the bone, even its minute histology .
    The proper development of the negative, after a proper exposure
 has been given, is a matter of the greatest skill and exactness, and
 it can only be done by one who knows just what information is
 desired. Too much or too little development will very often
 obliterate or fail to bring out the particular information desired .
 Suppose, for example, you were radiographing to find the actual
 size of a pulp-chamber, and you (or your photographer) developed
until you brought out in good definition the tooth and its root or
 roots ; on fixing, you would have no trace of the pulp-chamber ;
 while, if it were developed to the proper point to show the pulp-
 chamber most distinctly, the outline of the tooth would probably
appear to be seriously injured, and by all but the one knowing just
 what information was wanted the negative would be thought to
be spoiled : And so also with most cases it is imperative, for best
results, that the operator be his own photographer, and that he be
a good one .
    The conditions make a flexible photographic plate desirable,
which suggests a celluloid film such as that used for kodaks . Since,
however, we require great depth of detail, and since the rays have
the power of producing almost an equal action on a great number
of films placed one behind the other, it is clearly to our advantage
to use a greater thickness of emulsion than the ordinary kodak
films carry, and also a heavier celluloid, on account of conveuience
                                  9
in handling and developing, as it does not curl . I have had special
film made with as many as four layers of the sensitive emulsion,
one upon the other, but have gotten the best results with three
 layers . M. A . Seed & Co ., of St . Louis, have assisted me in pro-
 ducing an excellent special film, and I cheerfully recommend them
as careful manufacturers .
    The best method I have found of preparing film for use is to
take a piece of, say, four by five inches and lay a piece of bromide
 paper of the same size upon it with the emulsion sides or faces
together . Then stick the edges of two pieces of unvulcanized black
 dental rubber together after taking the paraffined linen from one
 side of each . On this lay the piece of film and bromide paper, and
over all put another side of the black rubber, allowing the edges of
the rubber, where they pass beyond the film, to unite,-which they
will do, as you know, very firmly by simply allowing them to touch .
Of course the above must be done in a totally dark room, or with
the most subdued ruby light . Dark rooms suitable for ordinary
photography would fog this film almost instantly .
   This piece of covered film can now be cut through with shears in
any direction into pieces the proper size for practical cases, and
part of it can be left for cutting at a moment's notice for a special
case . Prepared in this way, they do not need to be cut the exact
 size and shape required for the case in hand, but can instantly be
made any desired shape by simply bending a corner or end over and
allowing the rubber to touch itself, which will secure it firmly and
make a very smooth round corner to place against sensitive tissue .
 I have done much experimenting to see if anything better could be
 found for the coloring-matter of the rubber, but the lampblack
generally used is as transparent to X rays and as opaque to ordinary
 light as most substances that are also suitable, and the ordinary
black rubber can be had from any dental dealer . Red and pink
 dental rubbers are exceedingly opaque to the X rays, and make
most excellent screens for various purposes, such as shields and for
covering the tube to cut off stray X rays and fluorescent light in
fluoroscopic work, and have the advantages of lightness, easy
adaptability, and non-conducting or insulating properties . It is an
advantage to have the manufacturer of your dental rubber cut you
 some black about five by six or six by nine inches . The latter
 folds easily over a four- by five-inch film .
    I have carried on some extended experiments with the treatment
of photographic plates and films, with the view to increasing their
.sensitiveness to X rays and thereby shortening the time of ex-
posure, particularly with such chemicals as would tend to make
them orthochromatic or sensitive to the rays of the lower part of
the spectrum, on the theory that the emulsion changed the order of
some of the ether waves . My experimenting has been with quite
 satisfactory results, the sensitiveness of the film being increased
 from thirty to fifty per cent . with some treatments. In brief, the
best found consists in dipping the film into a solution of erythrosin
for about two minutes and allowing to dry in total darkness . After
this is done, it cannot be exposed to even a ruby light, and must be
                                  Io

used within a fortnight. I have recently, however, made such im-
provements in my own radiographing apparatus as to so far reduce
the time that this means was not necessary or desirable.
    When X rays fall upon certain salts they cause them to fluoresce ;
the chief of the salts so affected are calcium tungstate and bario-
platinum cyanid ; the latter is usually considered the better . When
this salt is evenly distributed upon a card or board, and the rays
are allowed to strike it, the illumination or fluorescence is very
bright, and any_ opaque object placed in the path of the rays will
produce a shadow . This you all know as the fluoroscope . It is, I
think, applied best in dentistry by placing a small screen of it, made
in the shape of a large mouth-mirror with the face turned the oppo-
site way, into the mouth behind the condition to be examined, and
then viewing the shadow cast upon it direct or with a mouth-mirror .
These are good forms and simple [demonstrated] . When using
this method the X-ray tube should be covered with something to
entirely shut off its white light . A heavy black cloth will do, but
the rubber spoken of is better . Use black over the part where the
rays come through, and red elsewhere over the entire surface of the
tube . This method of using the X rays requires a totally dark
room, and that the eyes of the operator be well accustomed to the
darkness . A large fluoroscope held against the outside of the face,
with the tube on the other side, will sometimes show something,
but comparatively faintly ; besides, the shadows of the teeth of the
opposite side seriously interfere . This last objection is overcome
by placing a tube inside the mouth, of which I shall soon speak .
    No part of the work requires. truer skill than interpretatiot
 of the negative or the positive it produces . A most intimate ac-
 quaintance is absolutely necessary, not simply with the anatomy of
the parts, but with the relative densities . The normal positions
 and relations must be known, and, as important as anything else, the
 angle of incidence of the rays ; also the relative positions of the
 film and partsradiographed, to each other and to the rays, particu-
 larly the point from which they are emitted . This makes it neces-
 sary that the operator keep a complete record of the distance of his
 tube from the film, and the direction or angles ; also a record of the
 relation of the film to the parts .
    By having a systematic method of charting, this becomes very
 simple, as I will show in this slide [exhibiting] . You will easily
 understand it, unless it be the plan of recording the angles . In the
 first the heavy black line represents the long axis of the tooth, and
 the dotted line its perpendicular. The line marked a represents the
 plane of the photograph film, and the other, with the arrow sign,
 the angle of the rays to the tooth and film . The second shows the
 lateral angle of incidence of the rays, the dotted line representing
 a perpendicular upon the natural plane of the tooth, which is the
 heavy line, and the pen line the true angle at which the rays struck
 this plane,-in this case about fifteen degrees to the right . Imagine
 yourself looking down upori it .
    We have now come to the most interesting and practical part,
  the technique of actual application . I should like to have been able
                               IF


to devote rny wholetime this afternoon to this part of the subject,
for much of what I have given could be gotten elsewhere, but it
was necessary in order for an understandir .g ot this more practical
part .
    First of all, have the patient comfortable : This is very desirable
and perfectly practicable . Probably half of our patients will be
children, and everything possible should be done to make the opera-
tion seem as harmless, insignificant, and simple as possible . My
best judgment and experience is to place patients in the dental
operating chair, make them as comfortable as possible, and leave
them so, except the natural tipping of the chair or rotating of their
 head .
    Now adjust your apparatus to the patient, which is exceedingly
 simple.
    Secure a small plate-glass-top table the length of the base of your
 coil and about ten inches wider, and of ordinary height, with a
 glass shelf midway below . The table must be mounted on rubber-
 tired wheels not less than four inches in diameter . On the shelf
 place your ammeter . On the top place the induction coil, which
 for our work should produce a ten- or, better, twelve- or sixteen-
 ~nch spark, also the tube-stand and a timepiece marking seconds .
 Place the timepiece so you can at the same time see through the
 glass top to watch the ammeter below, which is an indispensable
 part of the apparatus. Such a table can be had from or made by
 any maker of hospital furniture . Cast a heavy lead ring to load
 the base of the tube-stand if it be not already heavily loaded . Have
 a tube-stand that is itself a non-conductor and compact . It does
 not need a very long extension .
    Wrap some unvulcanized dental rubber around the stem of the
 X-ray tubes to clamp on to ; it holds the tube firmly, without danger
 of crushing. Use very heavy wire with all good connections for
 the primary circuit ; for the secondary to the tube a light wire will
 do, but it must be well insulated and, better, without any free points .
 This high-potential secondary current leaks off very rapidly from
 a bare wire or from exposed points or around a short tube . With
 a static machine half the energy may be lost from a few feet of bar e
     r or from an ex osed oint .    . Theor          both
                                           coil or interrupter ,wieoPpnt ,
 could be elsewhere in the room, as on a bracket on the wall, exeept
 for two reasons : First, the desirability of having both withiiieasy
 adjustment while operating, and, secondly, the difficulty of conduct-
 ing the high-potential secondary current without loss . The wires
 carrying the secondary current can be best insulated with what is
 known as high-pressure gum tubing, which has very thick walls ,
 such as I have here . Lead fuse wire inside makes an excellent and 1
 very flexible conductor :                        I                        ;il
     Nothing whatever, besides the operator's fingers, is necessary to         ;
 bold the sensitive film in place in the patient's mouth, and with thi s
 arrangement of apparatus the operator can hold the film with the
 fingers of his right hand, with the thumb and hand steadied against
 the face, by which he can detect the slightest displacement of th e
 film ; and with the left hand he can control and regulate every part hI
                                  12

of the apparatus and see everything. Every desirable .angle can be
secured in this way with . perfect convenience to both the operator
and patient . When radiographing either left or front superior or
inferior conditions, roll the table to the left side of the chair" and
stand behind the patient. For the various positions of the right
side of the patient, place the apparatus on the right or slightly back
of the patient, with the operator standing forward on the right .
   With the movements of the dental chair, tube-stand, and table,
every possible dental condition can be radiographed with perfect
ease for both patient, and operator .. For radiographing anterior
superior conditions, it is especially convenient to tip the chair back
to the reclining position and place the apparatus behind, with the
tube above the patient's forehead .
   This slide [exhibiting] shows the apparatus in position for a left-
side exposure.
. To have the apparatus working quietly is a very important item
for the comfort of the patient . The two,chief sources of noise are
the interrupter of the primary circuit and the series or parallel
spark-gaps of the secondary . It is a most lamentable fact that
many forms of apparatus are put on the market that make as much
racket and demonstration when running as a small foundry or nail-
factory. They frighten women and children exceedingly, which is
entirely unnecessary . First, do not use any but a comparatively
quiet interrupter ; and, secondly, place it on a sawdust or inclose it
under glass or place it in a tight box .
   Using a large mass of liquid in a Wehnelt or Caldwell inter-
rupter and covering it in this way, or, in one or two tight boxes, it
makes scarcely more noise than a boiling tea-ketttle, if heard at all .
When a heavy spark from the secondary takes place in the air it
makes a report like a pistol, and hence a spark-gap in series with
the tube is very noisy . It is also very often desirable to test the
internal resistance of a tube, which is most easily done by adjusting
a spark-gap parallel with the tube, gradually closing it until the cur-
rent will jump across rather than go through the tube . This also
makes much noise . This is not, by the way, a constant expression
of>the resistance of the tube, nor even relatively, unless a constant
volume of current is used which is impracticable . It is, however,
 very useful, and the noise from it, as also from the series-gap, can
be almost entirely done away with by having it occur within a
heavy glass tube (suggested by Professor Andrews) .
    Since these secondary series-gaps aid so much in regulating the
 penetration of the tube, it is desirable to be able to change them
while the'tube is glowing . But we cannot put our hands near them
 on account of getting a shock . I have overcome these difficulties
 by mechanical appliances, one of which I have here to show you .
 They cause the spark to take place within the glass cylinders
 attached to the heads of the coil, and both, positive and negative
 series-gaps and the parallel gap are under perfect control close
beside the switches of the primary current, all of which are within
 easy reach of the -left hand while holding the filni with the right .
 This is a material improvement.
                                   r3

    The length of exposure is dependent upon the volume and
quality of the X rays, the sensitiveness of the film, the information
 wanted, and, most important, the distance of the tube from the
 film . Some early investigators suggested, upon the theory of
rad`iant propagation, that the time should be inversely as the square
of the distance, as with light . Vandevyver (Journ. de Phys., 184)7,
page 23) and others have stated it to be inversely as the distance
 instead of the square of the distance . As this point is exceedingly
 important, I made many experiments to establish it, and I think
this one slide [exhibiting] does so, as do others made with tubes of
elifferent degrees of penetration .
    This shows three sections of a plate exposed separately to the
 same tube under the same conditions except distance and time .
 No . 460, the section to the left, shows the action on the plate with
the tube six inches away and a ten-second exposure . The center
 section shows the result with the time adjusted to the distance
inversely as the distance, which was six times the first, or thirty-six
inches, and hence the time sixty seconds . You observe that the
action on the plate is very much less than the first . The third aec-
tion to the right shows the result with the time inversely as the
square of the distance, or thirty-six inches and six minutes, which
is as nearly as is appreciable identical with the first exposure ; from
which we may conclude that approximately the time should be
inversely as the square of the distance .
    By far the most difficult part of the technique of application is the
securing of i-ays of proper penetration . Unfortunately, there never
has been any standard adopted, and we have no way of expressing
rays of various qualities, which would be a matter of very great
advantage . Roentgen discovered that the ratio of absorbability of
different substances was not proportional to their thickness, and
was different for different substances . On this hypothesis he made
a. radiometer of platinum foil 0 .0026 m .m . thick, with fifteen cir-
cular windows . In each of these he placed one additional . number
of disks or panes of aluminum foil of 0 .0299 M .M . On passing the
iays through this the penetrative power of the rays was determined
by noting the number of windows in which the absorbability was
the same in the platinum and aluminum . This idea is excellent,
but, since we require rays of such high penetration as to pass with
great ease through half an inch of aluminum, this method becomes
impracticable . Besides, it is very hard to read accurately, and has
not a wide range unless made very large . I have used with good
success a wedge of aluminum eight inches long and one inch wide,
and built up of layers each o.65 m .m . thick and each layer one-
fourth of an inch shorter than the last . One edge of the wedge is
covered with lead plate overlapping the faces one-fourth of an
inch, and each step numbered with lead figures . A radiograph of
it has already been shown . With it and the fluoroscope one can
judge as to the penetration of the rays with great accuracy, from
the distance to which it istransparent as compared with the opaque
lead backinz . This gauge has a great disadvqntage in size .
    The conditions demand that we have a gauge which we can not
                                     ;,4

only use with the fluoroscope, but also with each practical case, and
both test our work and also secure an accurate history of the rays
used" in each case,-preferably upon the negative itself . We can
not judge one caseaccu-rately by another, for it is scarcely possible
to get two cases with the conditions identical .
    I am glad to be able to recommend to you a radiometer which
answers largely all these desirable features, and at the same time is
very cheap and easy to secure in a pure form. It is made of pure
copper rolled gLccurately to o . i m .m . thickness and built up in twelve
steps,-the first being one inch wide and any length, say six inches,
and each succeeding layer one-twelfth inch narrower and the same
length. Put a piece of lead or fuse wire in the thick side . Flood
each side with rubber cement or glue, and wrap with a turn of thin,
strong paper and dry . From one end cut with shears some small
gauges, about one-eighth inch wide, which can be laid on the end
of the film where it extends beyond the teeth when radiographing .
 From this you will secure, on developing, a correct record of the
 actual rays used and their suitability for this case,-which is the
 short road to success, for from the information thus gained, and
 a larger scale or gauge made in the same way, and the fluoroscope,
 you can tell when you have secured the proper rays for the next
 similar case .
     I have tabulated the opacity of the various structures as com-
 pared with this standard, determined with the fluoroscope and
 photographs from a number of skulls, as well as from practical
 cases, and find the thickness to make considerable difference, as
 expected . Dry skulls have much less opacity than in life, and
 teeth give much greater contrasts . Watch for this in all exhibition
 radiographs, for it is easy to get good pictures of teeth in dry
 bones .
     The bone of the inferior maxilla of children in life has an opacity
 about equal to o . i 5 to 0 .3 m .m . pure copper, adults 0 .2 to 0 .4 m .m .,
 and old people o .2 to 0 .5 m .m .
      The bone of the superior arch of children, from o .2 to 0 .35 m .m .,
  adults 0.25 to 0 .45, and old people 0.3 to o .6 m .m .
      The opacity of dentin is difficult to determine, because the thick-
  ness varies so much, but is usually about equal to o .o5 to o .i m .m .
  more copper than the bone of children, and 0 .05 with adults, and
  0.05 to .nearly zero in old people . Of course, the bone being thinner
  through the inferior maxilla, the contrast is greater between it and
  the dentin of the roots .
      The opacity of the enamel of all ages is equal to from o . r to 0 .4
  m .m. greater than that of the dentin .
      Gutta-percha root-fillings are,, fortunately, quite as opaque as
  enamel, and fillings of the cements and the metals more so .
  Broaches are much more opaque than enamel . This slide (Fig . i)
  shows a standard of o .r m .m steps, also dry bone, dentin, enamel, a
  root-socket, a Donaldson broach, a white and a pink gutta-percha
  point, the pulp-chambers, the dental canal, and the cellular struc-
   :ure of the bone .
      In practical work select the rays that will not penetrate the more
                                    15


opaque structure, but will the less so ; and the more accurately this
selection is made the more distinct will be the shadow . You will
all understand now why pictures taken with rays that are not pene-
trating enough fail entirely to show contrast or definition . For-
tunately, tubes give out a mingled variety of rays as regards their
penetrative power, though a majority will have approximately the
same . This is to be seen in any of the slides showing a radiometer
gauge (see Fig . i) . This characteristic is not an unmixed advan-
tage, for, indeed, it is usually a disadvantage . Happily, it can be
remedied somewhat by regulating the nature of the secondary dis-
charge . It is only because there are some (though relatively few )

                                Fr G . i .




                      ~•~ :.~~=              '   i


                      ~^., .-


rays of high penetrative power emitted from tubes of really low
power that, by allowing the apparatus to run long enough, a pic-
ture-though a poor one-is possible .
   Strive to produce in the tube as limited a variety of rays as pos-
sible, and adjust for the majority .
   I must speak of the methods of mahi.ttg radiographs by plaeing
the tube within the mouth . This sounds formddable, but is thor-
oughly practicable, and was done first by Dr . Wm . Rollins in 1 $97 .
There are two chief methods . The first is by the placing of a very
small tube in the mouth, or one with a large auxiliary bulb outside,
and . attaching the negative wire from a mild static current to the
cathode terminal and the positive to a pad on the back of the
patient's neck or elsewhere . The connection is made to the posi-
tive terminal, which is inside the bulb in the mouth (and which
carries the anti-cathode) by means of a metal tip on the end of the
bulb, which makes contact with the soft tissues of the mouth . It is
not very painful, though very disagreeable . The other method is
similar, except that the patient is in electrical contact with one sid e
                                  i6

of a condenser of large capacity or the earth, the discharge
taking place through the tube . The current from either a static
machine or an induction coil can be used . The positive wire is
grounded., and has an adjustable spark-gap and is connected to
a metal handle, which supports the tube and which is held by the
patient . The metal of the handle is connected to an aluminum
sheath which covers the bulb to prevent accident from breakage,
and also to make connection with the positive pole . A specially
complete arrangement of this method has been presented by Dr .
Bouchacourt, of Paris . Compared with the ordinary methods, it
is very disagreeable to the patient ; and, in fact, I think few children
could be induced to tolerate it .
   However, neither of these methods is practical as compared with
the more simple method, since the point of emission is so close to
the object to be radiographed . Suppose the tooth to be radio-
graphed is a second bicuspid, one inch long, and the point of emis-
sion of the rays is inside the mouth one inch from the crown, and on
a line even with its morsal surface . The nearest the photographic
plate or fluoroscppe could get to the tooth outside would be about
three-fourths of an inch, then the shadow of the tooth would be one
and three-fourths inches long, as shown by this diagram at A [dem-
onstrating] ; and nearly all this distortion would be of the root, the
only part wanted. Imagine the distortion of an abscess at the apex
of the root . As a matter of fact, the shadows of the apex of the
root and an abscess, if there were one, would have to pass through
the anterior portion of the zygomatic arch, a dense bone, and would
be lost on account of the dispersion . The same tooth radiographed
with the tube outside and ten inches from and at right angles to
the film, which would be placed against the arch on the inside and
would necessarily bear away from the root, would produce exceed-
ingly slight distortion, as shown at B [demonstrating] . The latter,
on account of its length, has the extension lines cut off .
   By keeping a record of the lateral and elevation angles and dis-
tance, the exaet position of any part can readily be determined . It
is also well to keep for comparison a complete record of thecase
and conditions when radiographed . Since it is practically impos-
sible to identify negatives or prints when they get mixed up, espe-
cially when you get a lot, it is a great advantage to have a simple
means of numbering them . The best way I have found is to place
a small metal number upon the outside of the film on the part ex-
tending beyond the teeth . This number will be radiographed upon
the negative, and will appear, as you observe, upon all prints made
from it . The number is put into the record at the time of making
the exposure . (These numbers are very easily made of fine lead
fuse wire and stuck with paste on a sheet of paper, which is after-
ward cut, so that they may be readily torn off as needed . )
   There are a great many practical points that should be brought
out, like tricks in developing the negatives, controlling the vacuum
of tubes, etc., but time forbids . Those interested can get more
detail in a book, by the speaker, on "The Applications of Electricity
in Dentistry," which is nearly ready for publication .
                                 17

   Develop slowly with a weak developer, one that will not stain,
and aim for detail, not contrast. The thickly-coated films referred
to I leave in the developer from one to two hours .
   I will now show a few slides of practical cases, which represent
only a small portion of the field of application .
   The first slide (Fig . 2) shows the method of using the radi-
ometer, which here was much larger than need be, and had steps o . i
m .m . thick. This is a case of delayed dentition in a boy of seven-

                              FIG . 2 .' .




                              FIG . 3 .




teen years . You see the enamel sheath of the unerupted canine
distinctly from the dentin, and it has never formed properly at
the tip . This tooth has advanced one-eighth of an inch in one
year .
  The next slide (Fig . 3) shows the small amount of correction
nature has made in three months in a deformity due to but one
bicuspid forming, and that the first . It developed backward
against the first permanent molar and locked . The superior arch
on this side was greatly depressed, causing an intruded bite .
                                        18

Nature was making practically no advancement in correcting the
deformity of the position of the bicuspid, which was rotated about
half around, as you see . The deciduous molar was extracted and
an appliance adjusted to place the canine in its proper position to
permit the bicuspid to advance, which, as you see by the next slid e

                                     FIG . 4 .




                             -             5
                                       q
                                     F IG . ; .




                Frc . 6 .                                 F.ic . 7

       --




       I     ^'~
                    ~       •~



                            LJ
                                 ~


                                             ri   i ~r4




 (Fig . 4), it has done marvelously in sixty days' time, and it has
rotated . In this you see a radiometer in place . The same one can
be used indefinitely .
   Fig. 5 shows the movement of teeth in orthodontia, roots and all,
keeping the long axes of the teeth parallel . These teeth were nor-
mally touching
       . 6 shows.Fig a delayed bicuspid in a boy of fourteen years . Th e
                                         19

deciduous molar is very firm, and you see the reason : the distal root
is not absorbed .
   Fig: 7 shows another retained deciduous molar, which is also
very solid . Its successor is forming, but it is malposed ; it is
erupting lingually at about forty-five degrees, and is not producing
absorption of the deciduous molar .
   Fig . 8 is a case of delayed dentition (age fifteen), but in this
case the permanent laterals have never formed .
   Fig . 9 shows the teeth of a baby at fourteen months, when none
of the deciduous set had appeared . Not only are they to be seen ,

                   FrG . S .                        FIG, 9 .


            S .'




                                Y>   I




              1' I G .   10 .                   FIG. IT .




but also the tips of the forming crowns of the .permanent centrals
and the crypts of the laterals . This is of special interest, since the
child's father has not his permanent laterals ; and even before the
baby has got a temporary tooth we know he will get the permanent
teeth which his father laCks .
   Fig : zo shows a supposed abscess having a fistula, which proves
to be a so-called pyorrhea pocket . It was treated by root-amputa-
tion .
   Fig. ii shows that the missing bicuspid is not causing this
obscure abscess, in the fistula of which a lead wire was placed for
radiographing . The bicuspid has never formed . The abscess
clearly comes from the lateral, the apex of which is much absorbed .
 Note how plainly the floor of the antrum shows, and its most
ciependent point .
                                 20

   Fig . 1 2 shows the cause of an aggravated case of obscure neural-
gia, which is an abscess from a putrescent pulp ; the tooth fur-
nished no abnormal symptoms .

        FIG. 12 .                             FIG . 13 .




              ~~y ~•,~




            FIG . 14.    FIG . 15 .




         FIG . 16 .                                 FIG . 1 7 .




   Fig . 1 3 shows a very large abscess of the inferior maxilla, which
it has cut quite half in two .
   Fig . 14 shows the extent of absorption of the bone from an
abscess which made its demonstration and fistula beside the second
bicuspid . The radiograph showed it to come from the lateral ,
                                 21

which was treated accordingly by the amputation of its apex and
the abscess thoroughly drained at its most dependent point, marked
x . Repair was very rapid, and the next slide (Fig . 15) shows the
extent to which the bone was redeposited in three months .
   Fig . i6 shows the position of a retained canine of a lady aged
eighteen . The clinical evidence was very strong against its having
formed . On extracting the deciduous canine and attaching an
extruding appliance it came to proper position in a very short time .
   Fig . 17 shows the antrum of a lady about sixty . She had suf-
fered with acute empyema for some years . The radiograph reveals
a root penetrating the antrum, but entirely buried . This is the
only picture that has been retouched a particle, and in it the root
was intensified, the negative being weak .
   Fig. 18 shows an impacted lower third molar . It was treated
by first extracting the second molar, and then the third, after which
the roots of the second were filled and it was replaced . Apparently
excellent results


                 ..FIG 18 .                      Fic . 19 .




   Fig . Ig shows a case that was operated upon unsuccessfully for
the extraction of a supposed impacted third molar which had a
fistula externally . The radiograph shows that no third molar has
ever formed, and also shows an abscess at the apex of the second
molar, which later proved to be the cause of the external fistula .
   Another radiograph [exhibitingl, which is the last, shows the
great service of the rays in opening into a blind abscess . In this
case there was a ulind abscess connected with the superior central
incisor, and this abscess was developing back around the lateral .
When drilling through the process to get to it to make an artificial
fistula, which became necessary, I could not be sure of the accuracy
of the course or distance . When I thought I had reached it, I
placed a piece of lead wire into th~ artificial fistula and made a
radiograph, which showed that I had not quite reached it, though
in the proper course . The second picture shows the next test,
which proved the success of the work .
   I forgot to mention before that the piece of bromid paper placed
with the film would develop in a few seconds, giving you a very
quick picture, though not a splendid one as compared with the
negative .